GW7647

N.º de catálogoS8046 Lote:S804601

Imprimir

Datos técnicos

Fórmula

C29H46N2O3S

Peso molecular 502.75 Número CAS 265129-71-3
Solubilidad (25°C)* In vitro DMSO 100 mg/mL (198.9 mM)
Ethanol 25 mg/mL (49.72 mM)
Water Insoluble
In vivo (Agregue los solventes al producto individualmente y en orden.)
Homogeneous suspension
CMC-NA
≥5mg/ml Taking the 1 mL working solution as an example, add 5 mg of this product to 1 ml of CMC-Na solution, mix evenly to obtain a homogeneous suspension with a final concentration of 5 mg/ml.
Clear solution
5%DMSO 40%PEG300 5%Tween80 50%ddH2O

Validado por los laboratorios Selleck. Si necesita ajustes en esta formulación, póngase en contacto con nuestro equipo de ventas para pruebas personalizadas.

2.500mg/ml (4.97mM) Taking the 1 mL working solution as an example, add 50 μL of 50 mg/ml clarified DMSO stock solution to 400 μL of PEG300, mix evenly to clarify it; add 50 μL of Tween80 to the above system, mix evenly to clarify; then continue to add 500 μL of ddH2O to adjust the volume to 1 mL. The mixed solution should be used immediately for optimal results. 
Clear solution
5% DMSO 95% Corn oil

Validado por los laboratorios Selleck. Si necesita ajustes en esta formulación, póngase en contacto con nuestro equipo de ventas para pruebas personalizadas.

5.000mg/ml (9.95mM) Taking the 1 mL working solution as an example, add 50 μL of 100 mg/ml clear DMSO stock solution to 950 μL of corn oil and mix evenly. The mixed solution should be used immediately for optimal results. 
* <1 mg/ml significa ligeramente soluble o insoluble.
* Tenga en cuenta que Selleck prueba la solubilidad de todos los compuestos internamente, y la solubilidad real puede diferir ligeramente de los valores publicados. Esto es normal y se debe a ligeras variaciones entre lotes.
* Envío a temperatura ambiente (Las pruebas de estabilidad demuestran que este producto se puede enviar sin medidas de refrigeración.)

Preparación de soluciones madre

Actividad biológica

Descripción GW7647 es un potente agonista de PPARα, con EC50 de 6 nM, 1,1 μM y 6,2 μM para PPARα, PPARγ y PPARδ humanos, respectivamente.
Objetivos
human PPARα
(in an established cell-based reporter assay)
human PPARγ
(in an established cell-based reporter assay)
human PPARδ
(in an established cell-based reporter assay)
6 nM(EC50) 1.1 μM(EC50) 6.2 μM(EC50)
In vitro

GW7647 activa los PPARα, PPARγ y PPARδ humanos con EC50 de 0,006, 1,1 y 6,2 µM, respectivamente, en un ensayo de unión GAL4-PPAR. Se observan EC50 similares de 0,001, 1,3 y 2,9 con los receptores murinos.

Protocolo (de referencia)

Referencias

  • https://pubmed.ncbi.nlm.nih.gov/11354382/

Sellecks GW7647 Ha sido citado por 2 Publicaciones

Neutrophil CD11b is a pivotal PANoptosis marker correlated with disease activity in antineutrophil cytoplasmic antibody-associated vasculitis [ Apoptosis, 2025, 10.1007/s10495-025-02193-y] PubMed: 41100001
Investigation on regulation of N-acetyltransferase 2 expression by nuclear receptors in human hepatocytes [ Front Pharmacol, 2024, 15:1488367] PubMed: 39624836

POLÍTICA DE DEVOLUCIÓN
La Política de Devolución Incondicional de Selleck Chemical garantiza una experiencia de compra en línea fluida para nuestros clientes. Si no está satisfecho con su compra de alguna manera, puede devolver cualquier artículo(s) dentro de los 7 días posteriores a su recepción. En caso de problemas de calidad del producto, ya sean problemas relacionados con el protocolo o con el producto, puede devolver cualquier artículo(s) dentro de los 365 días a partir de la fecha de compra original. Siga las instrucciones a continuación al devolver productos.

ENVÍO Y ALMACENAMIENTO
Los productos Selleck se transportan a temperatura ambiente. Si recibe el producto a temperatura ambiente, tenga la seguridad de que el Departamento de Inspección de Calidad de Selleck ha realizado experimentos para verificar que la colocación a temperatura normal durante un mes no afectará la actividad biológica de los productos en polvo. Después de la recogida, guarde el producto de acuerdo con los requisitos descritos en la hoja de datos. La mayoría de los productos Selleck son estables en las condiciones recomendadas.

NO PARA USO HUMANO, DIAGNÓSTICO VETERINARIO O TERAPÉUTICO.